| Specifications | ||
| Model | A63 | |
| Measuring range | -40℃ to 300℃ (-40℉ to 572℉) | |
|
Infrared measurement Accuracy
|
-40℃ ≤ t ≤ 0℃: ±(1.5+0.1 x |t|)℃
|
|
| 0℃< t ≤300℃: ±1.5℃ or ±0.015 x t℃ | ||
| whichever is greater | ||
| -40℉≤ t ≤32℉: ±(3.0+0.1× x t-32|)℉ | ||
| 32℉< t ≤572℉: ±3.0℉ or ±0.015 x t℉ | ||
| whichever is greater | ||
| Temperature coefficient | ±0.1℃ / ℃ or ±0.1% / ℃ whichever is greater | |
| Emissivity | 0.95 (not adjustable) | |
| Distance to spot ratio | (D : S) 8:1 | |
| Spectral range | 5μm to 14μm | |
| Response time | ≤250ms (95% of reading) | |
| Repeatability | 1.0℃ or 1.0% whichever is greater | |
| 2.0℉ or 1.0% whichever is greater | ||
| Laser | Single laser (turn on/off automatically | |
| when measuring/stop measuring) | ||
| Laser power | <1mw | |
| Laser wavelength | 650 ±20 nm | |
| Laser spot diameter | 10mm ≤ d ≤ 15 mm at 10 m | |
| Probe measurement Accuracy | -50℃ to 300℃ (-58℉ to 572℉) | |
| -50℃ ≤ t < -30℃: ±1.0℃ | ||
| -30℃≤t≤100℃: ±0.5℃ | ||
| 100℃ < t ≤ 300℃: ±0.01 x t℃ | ||
| -58℉ ≤ t < -22℉: ±2.0℉ | ||
| -22℉ ≤ t ≤ 212℉: ±1.0℉ | ||
| 212℉ < t ≤ 572℉: ±0.01 x t℉ | ||
| Probe type | NTC | |
| Minimum measuring depth | 12.7 mm | |
| Auto power off | Infrared (not in Max / Min|T1 / T2 state) 60s ±5s | |
| Probe/infrared | ||
| in Max/Min|T1/T2 state 10min±1min | ||
| Operating temperature | 0℃ to 50℃ (32℉ to 122℉) | |
| Storage temperature | 30℃ to 70℃ (22°F to 158°F) | |
| Operating humidity | <90%Rh (non-condensing) | |
| Highest operating altitude | 2000 meters | |
| IP rating | IP65 | |
| Drop test | 1 meter | |
| Battery type | 2 x AAA alkaline batteries | |
| Operating time Infrared mode | >20h (continuous measurement) | |
| Probe mode | >80h (continuous measurement) | |
| Low battery indication | Yes | |
| LED alarm | Yes | |
| Data hold | Yes | |
| Unit conversion (℃/℉) | Yes | |
| Max/Min/Difference | Yes | |
| Display flipped | Yes | |
| Certificates | ||
| Probe | FDA certification Conform to FDA GRAS | |
| Laser safety standards | EN60825-1: 2014 and EN50689: 2021, CLASS 2 | |
| CE EN61326-1: 2013 | ||
| EN 61010-1: 2010+A1: 2019+AC: 2019 | ||
| UKCA Based on CE certification standards | ||
| RoHS SGS certification standards | ||
| EN13485 EN13485: 2001 | ||
| 1935/2004/EC (EC) 1935/2004 | ||
| General Characteristics | ||
| Product color | White + silver | |
| Product weight | 157g (without batteries) | |
| 180g (with 2 AAA alkaline batteries) | ||
| Product size | 55 x 28 x 178 mm | |
| Battery type | 2 x AAA alkaline batteries |