Type |
|
Finder 30.22.7.024.0010 |
Contact configuration |
|
2 Change Over (DPDT) |
Rated current / Maximum peak current |
|
2 / 3A |
Rated voltage / Maximum switching voltage |
|
125 / 250VAC |
Rated load AC1 |
|
125VA |
Rated load AC15 (230V AC) |
|
25VA |
Single phase motor rating (230VAC) |
|
------- |
Breaking capacity DC1: 30 / 110 / 220V |
|
2 / 0.3 / ---A |
Minimum switching load |
|
10 (0.1/1)mW (V/mA) |
Standard contact material |
|
AgNi + Au |
Coil specification |
|
|
Nominal voltage (DC Sensitive) |
|
24VDC |
Rated power |
|
0.2W |
Operating range |
|
16.8 to 36VDC |
Holding voltage |
|
8.4VDC |
Must drop-out voltage |
|
1.2VDC |
Technical data |
|
|
Mechanical life (cycles) |
|
10 x 10^6 |
Electrical life at rated load AC1 (cycles) |
|
100 x 10^3 |
Operate / release time |
|
6 / 2ms |
Insulation between coil and contacts (1.2/50 μs) |
|
1.5kV |
Dielectric strength between open contacts |
|
750VAC |
Ambient temperature range |
|
–40 to +85°C |
Environmental protection |
|
RT III |
Dimensions (L x H x W) |
|
20.3 x 11.4 x 10.4mm |
Approvals |
|
UL, VDE and CSA |