Model No. |
PM-A-1000AH-12 |
PM-A-1000AH-24 |
Output power continuous |
1000W |
1000W |
Instant Surge |
2000W |
2000W |
Standby Current |
< 0.5A |
< 0.4A |
DC Input Voltage |
10~15V |
20~30V |
AC Output Voltage |
100V/110V/115V/120Vac
or 220V/230V/240Vac |
100V/110V/115V/120Vac
or 220V/230V/240Vac |
Regulation |
+ 5% |
+ 5% |
Output frequency |
50Hz or 60Hz + 0.05% |
50Hz or 60Hz + 0.05% |
Efficiency |
> 85% |
> 85% |
Low Battery Alarm |
< 10.5V + 0.5VDC |
< 21.5V + 0.5VDC |
Low Battery Alarm & Shut-Down |
< 9.5V + 0.5VDC |
< 20.5V + 0.5VDC |
Over Heating Alarm |
> 60°C |
> 60°C |
Over Heating Alarm & Shut-Down |
> 65°C |
> 65°C |
Over Load Alarm |
> 1100W |
> 1100W |
Over Load Alarm & Shut-Down |
> 1300W |
> 1300W |
Input Low Voltage Protection |
Yes |
Yes |
Soft Start |
Yes |
Yes |
DC/AC Isolated |
Yes |
Yes |
AVR Design |
Yes |
Yes |
Output Short Circuit Protection |
Yes |
Yes |
Auto Temperature Control Fan |
Yes |
Yes |
Remote Control Interface |
Yes |
Yes |
Reverse Polarity Protection |
Yes (By Fuse) |
Yes (By Fuse) |
Fuse |
20A × 9pcs |
10A × 9pcs |
Dimensions (L x W x H mm) |
300 × 195 × 83 |
300 × 195 × 83 |
Gross weight (in Kg/s) |
4.00 |
4.00 |
Accessory |
DC Cable with O-ring |
DC Cable with O-ring |
Output Waveform
(Modified sine wave) |

|

|